The purpose of this study was to develop a methodology to detect spinosad which are difficult to analyze by multi-component simultaneous analysis of pesticide residues. We monitored spinosad due to the paucity of related information. The spinosad was determined using HPLC with UV detector at 250 nm. Correlation coefficient (r2) for standard curve of spinosad A and D at standard concentration of 0.1-5.0 mg/kg were 0.999, respectively. Limit of quantitation (LOQ) of HPLC analysis was 0.005 mg/kg while limit of detection (LOD) was 0.001 mg/kg. Recovery experiments were conducted on five representative agricultural products to validate the analytical method. The recovery of proposed methods ranged from 74.9% to 104.0% and relative standard deviations were less than 10%. Spinosad residues were investigated in 16 commodities collected from 22 provinces. In this study, residues on all samples were not detected.
목차
서론
재료 및 방법
실험재료
표준품 및 시약
표준용액의 제조
시료추출 및 정제
분석기기 및 조건
결과 및 고찰
시험법 개선
검출한계 및 정량한계
직선성 및 재현성
회수율
스피노사드 잔류실태조사 결과
요약