원문정보
Reversed Micellar Protein Extraction in a Hollow Fiber Membrane Extractor
초록
영어
Solubilization phenomena of a protein in a reversed micellar solution were investigated and a hollow fiber membrane extractor was tested for reversed micellar protein extraction equipment. Alkaline protease was used as a model protein compound and the reversed micellar solution was consisted of AOT and isooctane. It was found that protein solubilization was strongly influenced by ionic strength and pH. The distribution coefficient of the protease between the aqueous solution and the AOT/isooctane solution was also observed to be as high as 4.0 within the scope of this experiment. A hollow fiber membrane extractor was constructed and tested for the protein extraction. The overall mass transfer coefficient at a typical experimental condition of this study was observed to be 6.7x10-5cm/s. It was also found that the mass transfer resistance on reversed micellar solution was the dominant resistance for the protein transfer.
한국어
역미생용액으로 단백칠을 추출하는 공정에셔 수용 액의 이온세기와 pH가 중요한 공정변수가 된다. 본 실험에셔 사용한 역미생용액은 AOT를 Isooctane에 5 50mM의 농도로 용해시켜 사용하였고 단백칠로서 alkaline protease를 model compound로 사용하여 추출설험을 수행한 결과 본 설험의 범위에서 pH가 낮을수록, 이온세기가 낮을수록 효율적인 추출이 이루어졌으며, pH가 3.0 그리고 이온세기가 O.lM KCI 일때 분배계수가 4.0으로 가장 크게 나타났다. 단백질의 용매추출 장치로서 설관막 모률을 제작 하여 alkaline protease를 역미생을 이용하여 용매 추출을 수행하였는 바, 단백질 분리공정에 효과적인 장치로 사용될 수 었음을 보여주였다. 본 실험의 조 건에서 총괄물질전달계수 Ko가 6.7x10-5cm/s이었으며 유기용매상의 개별물칠전달저항이 수용액상의 물질전달저항보다 중요하게 나타났다. 실관막 추출 장치의 조업시 설관막 양쪽 상의 압력차를 0.1kg/cm2 이하로 조절하여 emulsion의 형성을 방지할 수 있었다
목차
서론
재료 및 방법
분배계수 측정 실험
실험장치 및 방법
결과 및 고찰
역미셀용액의 단백질 용해 특성
실관막 장치에서의 단백질 추출
요약
감사
참고문헌