DIGOXIN 용량결정 방법들의 평가

원문정보

Evaluation of Digoxin Dosing Methods

류윤미, 신완균, 이명걸, 이민화

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The ability to precisely predict serum digoxin concentration using 7 published methods in a group of 50 patients was undertaken. Two methods of estimating creatinine clearance and two estimates of lean body weight were employed as input variables using the 7 dosing methods. TDX was used to determine the nadir SDCs(serum digoxin concentrations) in 50 in patients meeting predetermined study criteria. All patients, whose ages ranged 19-71 years, had steady-state digoxin levels, were in oral digoxin, and were free from liver dysfunction, thyroid dysfunction and renal failure. The correlation coefficients(r) of predicted versus observed SDCs were determined,. and mean error(ME) was determined for each method to reflect bias, respectively. No substantial differance in predictive reliabliity was evident among the methods studied in total group. Poor correlations existed between predicted and observed SDCs(r<0.4) and these correlations were not significantly affected by age and gender. But relatively higher correlation and lower ME was founded for the CHF group in Jelliffe method(r=0.5, p<0.05).

저자정보

  • 류윤미 Ryu, Yunmi. 서울대학교 병원 약제부(Seoul National University Hospital pharmary)
  • 신완균 Shin, Wan-Gyoon. 서울대학교 병원 약제부(Seoul National University Hospital pharmary)
  • 이명걸 Lee, Myung-kul. 서울대학교 약학대학(Collegy of pharmacy. Seoul national university)
  • 이민화 Lee, Min-Hwa. 서울대학교 병원 약제부, 서울대학교 약학대학(Seoul National University Hospital pharmary, Collegy of pharmacy. Seoul national university)