earticle

논문검색

평지붕 옥상층을 활용한 분산형 저류시스템의 타당성에 관한 연구

원문정보

A Study on the Feasibility of Separated Stored Rainwater System using the Flat Roof Top

장승재

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The purpose of this study is to supply preliminary data of separated stored rainwater system using variable roof drain on flat roof. After 2000 year, the inundation damage in down town city is increased by localized heavy rainfall. The exiting stored rainwater system such as water-storage dam and dike has demerits that high construction cost and long-term construction periods. But the separated stored rainwater system using variable roof drain can be cut down construction cost about 1/10 compared with the construction cost of exiting stored rainwater system. As water temperature on roof top equipped with variable roof drain is lower than outdoor air temperature, the cooling road of roof top can be reduced. Therefore, the stored water on the flat roof can be occurred cooling effect such as roof pond type that can be reduced cooling road by evaporation.

목차

1. 서론
 1.1 연구의 목적
 1.2. 연구의 방법
2. 집중형 저류시스템과 분산형 저류시스템의 개념
3. 가변 루프드레인의 높이
4. 집중형 저류시스템과 분산형 저류시스템과의 경제성비교
5. 가변 루프드레인 설치에 따른 옥상층의 물의 온도및 증발량과 증발손실열량 계산
6. 결론
참고문헌