원문정보
A Study on the energy analysis on the school building by overhang and arrangement
학교건물의 배치형태와 차양에 따른 에너지 분석에 관한 연구
초록
영어
The energy consumption in school building performed using Visual Doe 3.1. The analysis of energy consumption divided 3 types which are (1) the classroom is located to southward (2) the corridor is located to southward (3) the classroom with fixed overhang is located to southward. When Compared the classroom is located to southward and the corridor is located to southward, the classroom is located to southward is reduced 40% on illumination load and 10% on cooling load. When Compared the classroom is located to southward and the classroom with fixed overhang is located to southward, the classroom with fixed overhang is located to southward is raised 10% on illumination load and is reduced 40% on cooling load.
목차
1. 서론
1.1 연구의 배경 및 목적1)
1.2 연구의 대상 및 방법
2. 대상건축물의 개요
2.1 건축 개요
2.2 외피구조
2.3 차양구성
3. 건축물의 에너지 성능해석
3.1 시뮬레이션 조건
3.2 에너지 성능해석
4. 결론
참고문헌