A Study on the Application of Isolation System in Main Control Room of Nuclear Power Plant
초록
영어
An experimental and analytical study was performed to apply the friction pendulum system(FPS) to main control room of nuclear power plant. A friction pendulum bearing was fabricated and dynamic response of the bearing was evaluated. A partial model of main control room attached FPS was tested on the shake table. The model consisted of a cabinet, access floor(2.3m x 2.3m) and 4 friction pendulum bearings. Artificial time history based on floor response spectrum of main control room was used as earthquake input signal in the test.
Comparisons between analytical study and experimental study were conducted in order to verify the results as well as to extend the experimental study to the range of parameters which could not be experimentally studied.
목차
1. 서론
2 FPS의 동적 물성치 평가
2.1 FPS의 수학적모델
2.2 FPS의 물성치 결정을 위한 예비해석
2.3 물성치 평가시험
3. 부분 면진시스템 예비해석
3.1 전산해석모형
3.2 사례해석
4. 3차원 면진시스템의 성능평가
4,1 면진시스템 제작
4.2 부분모형 실험 및 해석결과의 비교
4.3 주제어실 층 면진 성능 평가
5. 결론
참고문헌