B형 삼중수소 운반용기 안정성 평가
초록
영어
A transport container for a 500 kCi tritium storage vessel was developed, which could be used for the transport of metal tritide from Wolsong TRF facility to a disposal site. The structural, thermal, shielding, and confinement analyses were performed for the container in a view of Type B. As a result of structural analysis, the developed container sustained its integrity under normal and accidental conditions. The maximum temperature increase of the inner storage vessel by radiation was evaluated at at room temperature. In fire test, The thermal barrier of container sustained the inner vessel at after 30 min, which temperature was allowable for the container integrity since maximum design temperature of inner vessel was . In the evaluation of the shielding, the activity of radiation was nearly zero on the outer surface of inner vessel. Consequently the transport container for a 500 kCi tritium was evaluated to pass all the safety tests including accidental condition, so it was concluded that the designed transport container is proper to be used.
한국어
월성 원자력 발전소의 TRF 시설에서 수집된 트리튬을 metal hydride 형태로 보관하고 있는 500 kCi급 트리튬 1차 저장용기를 발전소 밖의 폐기물 저장고로 안전하게 운반하기 위하여 트리튬 운반용기를 개발하였다. B형 운반용기의 기술기준을 적용하여 구조평가, 열평가, 방사선차폐평가, 격납평가 등을 수행하여 운반용기의 안전성을 분석하였다. 트리튬 운반용기는 정상운반조건 및 사고운반조건에서도 격납 경계가 손상되지 않는다고 평가되었다. 붕괴열로 인한 운반용기 내부 저장용기의 온도상승은 수치해석 결과, 원통형 모델에서는 로 나타났다. 운반사고 조건에 대한 열 평가로서 외부환경에 30분간 노출되었을 경우에는 단열재만의 열차폐를 고려하여 계산한 결과, 약 로 나타났으며, 내부 온도 상승은 1차 격납 경계인 1차 저장용기의 허용 온도인 에도 미치지 못하였다. 격납 차폐 평가에서도 사고조건인 의 외부 환경에 노출된 경우에서도 충분히 운반용기의 격납 성능을 유지할 수 있다고 판단되었다. 방사선에 대한 차폐 특성을 조사한 결과, 트리튬에서 발생된 선량은 1차 저장용기 외부 표면에서 0으로 계산되었다. 이상과 같이 500 kCi 급 트리튬 운반용기에 대한 안전성을 평가한 결과, 운반사고조건에서도 트리튬 운반용기는 전혀 이상이 없는 것으로 나타났다.
목차
요약
I. 서론
II. 방사성내용물의 개요
III. 법적 적용기준
IV. 구조 평가
가. 구조 설계
나. 운반용기 재료
다. 정상운반조건에 대한 구조평가
라. 운반사고조건에 대한 구조평가
V. 열 평가
가. 붕괴열 평가
나. 정상운반조건에 대한 열평가
IV. 격납 평가
가. 정상운반 조건에 대한 격납평가
나. 운반사고 조건에 대한 격납평가
VII. 방사선차폐 평가
VIII. 결론
참고문헌