영어

Window System has a problem with insulation on building wall comparison with other portions. Recently, in all over the world, technologies and research for improvement of insulation performance with window system were actively studied. This study has been considered about components of window system and evaluated insulation performance of triple window system through the tests of U-Value of window system and simulated model. It was evaluated window
system that widely used in domestic or overseas. Therm5.0 and Window6.0 were used for simulation available for heat analysis from stationary state of two-dimensional simulated model. As a result, the best components of each portion on window system were PVC frame, Plastic spacer and Low-e glass and the super insulation window system was triple glazing window system applied these components. The U-Value of this super insulation triple window system was 1.325 W/㎡K and it will be expected saving energy window system.

목차

Abstract
 1. 서론
 2. 창호의 단열성능 영향요소 사용현황
  2.1 Air Space
  2.2 간봉(spacer)
  2.3 유리
  2.4 창틀(frame)
 3. 창호의 단열성능실험과 시뮬레이션보정
  3.1 삼중창 시스템의 열관류율 실험
  3.2 시뮬레이션 보정
 4. 고단열 삼중창 시스템의 열관류율 평가
  4.1 프레임의 변화에 따른 열관류율 평가
  4.2 간봉에 따른 열관류율 평가
  4.3 유리두께별 열관류율 평가
  4.4. 유리의 방사율에 따른 열관류율 평가
  4.5 고단열 삼중창 시스템의 열관류율
 5. 결론