Higher concentrations of MLSS(Mixed Liquor Suspended Solis) in BNR(Biological Nut-rient Removal) systems and stringent effluent suspended solid concentration requirements demand a good design practice for secondary clarifiers. Although SOR(Surface Overflow Rate) and SLR(surface Loading Rate) are commonly used in secondary clarifier design, these parameters do not reflect hydraulics and solid-liquid separation within clarifiers. In this paper, the Clari-2D model that can simulate hydraulic and MLSS settling behaviors was used to evaluate secondary clarifier design in P water reclamation plant in Gyeonggi province, S. KOREA. Three parameters in settling equation were experimentally defined : Vmax is 14.718 m/hr, K1 is 0.242 m3/kg and K2 is 20 m3/kg, respectively. Steady and dynamic state simulations were carried out to find a diurnal inflow effect on clarifier. Also, effects of chemical addition to enhance phosphorus removal were simulated. With chemical addition, the hourly maximum effluent SS(suspended solid) concentration was found 8.8 mg/L. This concentration meets the SS effluent requirement that is 10 mg/L.
목차
Ⅰ. 서론
Ⅱ. 연구 방법
1. Clari-2D 모델
2. 경기도 S하수처리장 MLSS 침전 특성 실험
3. 경기도 S 하수처리장 MLSS의 computersimulation을 통한 K2값 결정
Ⅲ. 경기도 P 수질복원센터 장방형 이차침전지 시뮬레이션
1. 약품 투입을 하지 않은 경우의시뮬레이션 결과
2. 약품이 투입된 경우의 시뮬레이션 결과
IV. 결론
참고문헌