원문정보
Performance Evaluation of the Void Removal on Top-Down Joint Part In Field Study
초록
영어
The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method.
The result of study is below.
(1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in column joint. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.
……………………………………………………………………………………………………………………………
목차
1. 서 론
2. 실험계획
3. 실험방법
3.1 수평 Joint 시험체 타설
3.2 경사 Joint 시험체 타설
4. 실험결과
4.1 수평 Joint 시험체
4.2 경사 Joint 시험체
5. 결 론
참고문헌