초록

영어

Exposure to extremely low frequency (ELF) electromagnetic fields (EMFs) from power transmission and distribution facilities has gained increasing attention with rising power demand driven by artificial intelligence (AI). This study proposes a practical EMF measurement method suitable for domestic power facility environments in Korea. Field measurements were conducted on 345 kV and 154 kV overhead transmission lines and 22.9 kV distribution lines based on ICNIRP guidelines and international standards IEC 62110 and IEEE Std 644. Measurements were performed at the maximum sag point at different lateral distances and representative heights. The results show that EMF levels were highest directly beneath the conductors and decreased rapidly with distance, while all measured values remained well below domestic exposure limits.

목차

Abstract
1. 서론
2. 극저주파 전자계 및 허용 기준
3. 송전선로 전자계 측정
3.1 국내 · 외 전자계 측정 지침
3.2 전자계 측정 방법
3.3 전자계 측정 장비
3.4 가공 송전선로의 측정결과
4. 결론
후기
References

저자정보

  • 정민창 Minchang Jeong. Dept. of Electrical Eng., Wonkwang University
  • 김재혁 Jaehyuck Kim. Member, Professor, Dept. of Electrical Engineering, Innovation Center for Engineering Education, Wonkwang University

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.