earticle

논문검색

Technology Convergence (TC)

Characteristics of Motion State Changes in Human Movement for Triangular Configuration Method Using Load Cell Sensors

원문정보

Jeong-Lae Kim, Kyu-dong Kim

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Triangulation Measurement Method (TCMM) technology, which uses load cells to measure an object's weight or force, continues to advance. Load cell technology is developed for high precision and sensitivity, and is used for extremely precise measurements in the development of nano and micro sensors. Systems employing Triangulation Measurement Method (TCMM) collect electrical signals from load cells to measure vertical load changes resulting from shifts in an object's center of gravity, thereby obtaining load variations over time. The minute shaking of an object reflects slight sway or balance movement as vibration. The signal amplification section in the load cell integrates the steady signal through a specific process before passing it to the microprocessor. The transmissible signal is configured for real-time data transmission and remote monitoring via a smart load cell with an embedded wireless communication module. Changes in the human body are measured as mechanical motion, generating vibrations within a frequency range of 1 to 20 Hz. The results of the Triangular Configuration Measuring Method System (TCMMS) showed motion state changes due to vibration. The wobble motion state of the TCMMS-FA-τMAX was 26.03±5.53 units from the sprinkling monochrome-dot echo, while the wobble motion state of the TCMMS-CO-τMAX was 12.13±2.19 units, the wobble motion state of the TCMMS-FL-τMAX was 4.18±0.74 units, and the wobble motion state of the TCMMS-VI-τMAX was (0.74±0.11) units. We can utilize load cells designed using this Triangular Configuration Measuring Method (TCMM) for precision medical devices, advanced industrial measuring instruments, and more. Load cells can be employed to measure forces such as tension, compression, pressure, or torque, and can serve as indicators for monitoring cardiac activity, similar to an electrocardiogram.

목차

Abstract
1. INTRODUCTION
2. Materials and Methods
2.1. Triangular Configuration Technology (TCT)
2.2. Wobble Triangular Configuration Methods
2.3. Wobble Triangular Configuration Form
2.4. Triangular configuration measuring Technique Dot
2.5. Triangular configuration measuring Form
3. Result
3.1. Wobble triangular configuration-form data sequence
3.2. Wobble triangular configuration-form technology
3.3. Improvements of wobble triangular configuration-form sequence selections
4. Discussion
5. Conclusion
REFERENCES

키워드

  • Wobble motion state
  • Triangular configuration measuring method system
  • Triangular configuration measuring method
  • Load cell.

저자정보

  • Jeong-Lae Kim Professor, Dept. of Biomedical Engineering, Eulji Univ., Korea
  • Kyu-dong Kim Professor, Dept. of Medical IT, Eulji Univ., Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.