원문정보
Influence of Spatial, Environmental, and Managerial Factors on Stairwell Fire Door Opening in Apartment Buildings
초록
영어
Purpose: This study analyzes the impact of spatial, environmental, and management factors in apartment buildings on the usability of stairwell fire doors, identifies issues, and suggests improvement measures. Method: Seven research hypotheses were established, and a checklist-based field survey was conducted. Survey items included building scale, layout, age, lobby floor area, window installation, fire door condition, type of door closer, presence of obstructions, and door operation. These factors were analyzed for their influence on fire door malfunction and opening rates. Result: Many fire doors remained open regardless of door closer type, with 54.9% of malfunctions caused by intentional obstruction. Fire door opening rates were significantly associated with building age, decreasing with larger lobby areas but increasing with higher levels of obstructions near doors and within stairwells. Conclusion: Expanding lobby floor area and managing obstructions are effective in reducing fire door opening rates, while resident education and awareness campaigns are also necessary.
한국어
연구목적: 본 연구는 공동주택의 공간·환경적 특성과 관리 요인이 계단실 방화문 사용성에 미치는 영향 을 분석하고 문제점을 도출하여 개선방안을 제시하고자 한다. 연구방법: 공간·환경·관리 요인에 따른 7 개 가설을 설정하고 체크리스트를 활용한 현장조사를 실시하였다. 주요 조사항목은 건물 규모, 공간적 형태, 경과 연수, 승강장 바닥면적, 창호 설치 유무, 방화문 상태, 도어클로저 종류, 적치물 유무 및 방화 문의 개폐 여부 등이며, 이를 통해 요인이 방화문의 비정상률과 개방률에 미치는 영향을 분석하였다. 연 구결과: 다수의 방화문이 도어클로저 종류와 관계없이 개방된 상태였으며, 비정상률의 54.9%는 임의 적치물에 의한 고정에서 비롯되었다. 또한 방화문 개방률은 건물 경과 연수와 유의한 상관이 있었고, 승 강장 바닥면적이 넓을수록 낮은 경향을 보였다. 반면 방화문 인접부 및 계단실 적치물이 많을수록 개방 률이 증가하였다. 결론: 승강장 바닥면적 확대와 철저한 적치물 관리가 방화문 개방률 저감에 효과적이 며, 입주민의 인식 개선을 위한 교육·홍보가 필요하다.
목차
요약
서론
이론적 고찰 및 연구의 범위
공동주택의 조사범위 및 유형
계단실 종류
방화문 도어클로저 종류 및 정의
실태조사의 대상 범위
연구설계
조사대상물 및 조사 범위 설계
조사항목
연구가설
실태조사방법 및 기간
연구결과
방화문의 비정상률에 관한 원인 분석
방화문의 개방률에 미치는 영향 분석
결론
Acknowledgement
References