earticle

논문검색

<학술연구>

액체수소 컨트롤 밸브의 MLI 두께 설계

원문정보

Thickness design of MLI for control valve for LH2

곽효서

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

This study establishes a transient CFD and coupled CFD-thermal analysis method for evaluating the insulation performance of a liquid hydrogen control valve system incorporating an MLI-VCS-MLI configuration. Parametric analysis was conducted by varying the thickness of MLI 2 (50–200 mm) to assess its impact on the temperature distribution and heat flux within the valve body and insulation layers. The results indicate that increasing the thickness of MLI 2 significantly reduces heat flux and improves insulation effectiveness, with the highest heat flux occurring at the outermost MLI layer exposed to ambient conditions. These findings provide valuable insights for optimizing insulation design in liquid hydrogen storage and transport systems, contributing to enhanced thermal management and energy efficiency.

목차

Abstract
1. 서론
2. 컨트롤 밸브의 유한요소해석
2.1 Analysis model and CFX-Pre
2.3 CFD-thermal analysis
3. Parametric study
3.1 Parameter set
3.2 Result of parametric study
4. 결론
후기
References

저자정보

  • 곽효서 Hyo-seo Kwak. Assistant professor, Mechanical Engineering Major, Dong-Eui University

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.