골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구

원문정보

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture

이명곤

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The objective of this finite element method study was to analyze the stress distribution inducedon a supporting bone by 3.75, 4.0, 5.0diameter of dental implant fixture(13length). 3-dimensional finite element models of simplified gold alloy crown(7height) and dental implantstructures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supportingbone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 Nwhich was forced over occlusal plane of gold alloy crown vertically.Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75diameter offixture), 8.885(4.0diameter of fixture), 6.301(5.0diameter of fixture) and the highest vonMises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.