This paper presents a comparative analysis of the impact of smoke barriers on the Available Safe Evacuation Time (ASET) in hospital buildings after a fire, based on the Korean and Chinese standards. Three scenarios are established according to the width specifications of smoke barriers in both standards. Fire simulations are conducted using PyroSim software, and the effects of smoke barriers on ASET are examined from four aspects: temperature, visibility, CO concentration, and O2 concentration. The simulation results indicated that the ASET under both the Korean and Chinese standards are similar. The study also concluded that, regardless of the standard, smoke barriers play a role in restricting the spread of fire smoke. When the width of the smoke barrier is too large, its effect on improving the ASET on the floor where the fire originates is limited, but it has a more significant effect on the ASET on other floors.

목차

Abstract
1. INTRODUCTION
2. RESEARCH MODEL
3. RESEARCH METHODS
3.1 PyroSim Software
3.2 Model Building
3.3 Scenarios Design
3.4 Initial Condition Setting
4. SIMULATION RESULTS AND ANALYSIS
4.1 Simulation Results According to Korean Standards
4.2 Simulation Results According to Chinese Standards
4.3 Analysis of Simulation Results
4.4 Application Plans
5. CONCLUSION
REFERENCE

저자정보

  • Xiaopei Liu Lecturer, 113001 School of Environmental and Safety Engineering, Liaoning Petrochemical University, Fushun, P.R. China
  • Hasung Kong Professor, 55338 Dept. of Fire Protection and Disaster Prevention, Woosuk Univ, 443 Samnyero, Samnye-eup, Wanju-gun, Jeollabuk-do, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.