원문정보
초록
영어
In the development of a digital multi-process welding machine, we aimed to analyze the heat dissipation effects resulting from changes in the transformer's shape. Two installation configurations for the transformer, vertical and horizontal, were proposed. Thermal-flow analysis was conducted for the welding machine, taking into account variations in spacing between each proposed configuration. The results indicated that the shape and spacing of the components did not significantly alter the airflow around the reactor coil, which is the main heat-generating component of the machine. When comparing the heat dissipation effects across models with different transformer spacings, it was observed that models with narrower spacing exhibited improved heat dissipation, while the vertical configuration demonstrated a slightly higher heat dissipation effect overall. Transient analysis revealed the irregularities in internal flow and the resulting scattered temperature distribution over time within the welding machine.
목차
1. 서론
2. 용접기 방열해석
2.1 방열해석 방법
2.2 해석변수
3. 정상상태 방열해석
4. 과도상태 방열해석
5. 결론
References