원문정보
초록
영어
An electric initiator is a component that is located in the thermal battery or propulsion unit to transfer energy first. Initiator tests include X-ray test, non-destructive leak testing, circuit/insulation resistance test, and CBT (Closed Bomb Test). Among them, CBT is a key element in evaluating the performance of initiator, and the reliability of the test results is important for judgment of the required performance. This study conducted inter-laboratory comparative tests to secure the reliability and repeatability & reproducibility of the initiator CBT. A comparative test was conducted with a mass production acceptance test agency to verify whether the reliability was secured.
목차
1. 서론
2. 초기 도입 CBT를 이용한 시험
2.1 노이즈 발생 현상 개선
2.2 초기 도입 CBT 치구 - 시험소 간 비교시험
2.3 초기 도입 CBT 치구 설계미흡 사항검토
3. 개선 CBT 치구를 이용한 시험
3.1 개선 CBT 치구 - 시험소 간 비교시험
3.2 개선 CBT 치구 T-검정
4. 결론
References