earticle

논문검색

학술연구

터널 경사갱용 저주파 소음기의 주파수 특성 분석

원문정보

Analysis of Frequency Characteristics of Low-frequency Silencers for Tunnel Inclined Shafts

고태환, 김동현, 강부병

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The performance of various types of silencers used to reduce the micropressure waves radiated from ventilation holes and inclined shafts, which are being studied as measures to reduce micropressure waves in railway tunnels, was evaluated to find an effective silencer. In order to find the optimal silencer, the magnitude and frequency characteristics of the pressure waves emitted from the inclined shaft were analyzed to find an excellent silencer. The evaluation showed that the model with a porous cylinder and a small diameter outer tube was the simplest but performed the best.

목차

Abstract
1. 서론
2. 축척 모 델 주행시험
2.1 주행시험 장치 및 소음기 형상
3. 소음기 주행시험 결과
3.1 속도별 고효율 소음기 통과 미기압파 특성
3.2 소음기 방식별 미기압파 특성
4. 결론
후기
References

저자정보

  • 고태환 Taehwan Ko. Test & Certification Center, KRRI
  • 김동현 Dong Hyeon Kim. Hyper Tube Express (HTX) Research Team, Korea Railroad Research Institute
  • 강부병 Bu-Byoung Kang. Department of Railway Vehicle System Engineering, Woosong University

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.