원문정보
황산을 이용한 동전기적방법에 의한 방사능오염토양 복원 연구
초록
영어
H2SO4 and citric acid were used as additives for the electrokinetic remediation experiment to increase removal efficiency of Cs and Co from the radioactive soil waste stored for more than 10 years. The average effluent velocity discharged from the elctrokinectic remediation experimental column was 2.010 cm/min and the discharged soil wastewater volume for 10 days is 3.6 pore volume of the column. 97% of Co in the column was decontaminated for 10 days of operation, while only 54% of Cs was decontaminated. These results are considered that the absorption equilibrium coefficient of Cs is higher than that of Co. The predicted values of the residual concentration by the proposed mathematical model were well coincided with the experimental results within the experimental error range
한국어
10년 이상 된 방사능오염 토양에서 동전기적 방법에 의한 Cs과 Co의 제염효율을 높이기 위해 HSO과 시트르산을 첨가제로 사용했다. 동전기 토양복원 컬럼의 방출수 평균속도는 2.0 cm/min이고, 10일 동안 방출된 토양폐액의 부피는 컬럼의 3.6 공극부피다. 10일간 Cs 의 제거효율이 54%에 불과한 반면에, Co는 97%나 제거되었다. 이것은 Cs의 흡착평형계수가 Co 보다 크기 때문이라고 생각된다. 본 연구에서 제시한 수학적 모델에 의한 컬럼 잔류 오염도는 실험 오차 범위에서 실험결과와 잘 일치하였다.
목차
요약
I. 서론
II. 이론 및 모델링
1. 오염물질의 이동구조
2. 전하방정식 및 평형
3. 초기 및 경계조건
4. 코드개발
III. 토양 복원 실험
1. 입력파라미터 측정
2. 최적추출제 선정 실험
3. 동전기 실험
IV. 결과 및 고찰
V. 결론
감사의 글
참고문헌