초록
영어
This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.
목차
1. 서론
2. 이론적 배경
2.1 소방계획서의 이론적 고찰
2.2 연구모델
2.3 염화수소의 물리ㆍ화학적 특성
3. 시나리오 구성
3.1 화재, 폭발, 독성 시뮬레이션 프로그램
3.2 누출 사고시나리오
3.3 입력변수 및 입력값
3.4 평가 기준
4. 실험결과 및 논의
4.1 실험결과
4.2 논의
4.3 논의에 따른 개선방안
5. 결론