영어
This study aimed to present an effective methodology for calculating and analyzing greenhouse gas emissions in small and medium-sized enterprises (SMEs) by selecting the ‘A’ company, located in the Banwol-Sihwa Industrial Complex, as a testbed. The analysis of the greenhouse gas emissions at the 'A' company showed that as the company's production volume increased, the Scope 1 and Scope 2 emissions rose from 651 tCO2eq/year to 832 tCO2eq/year, and Scope 2 emissions increased from 17,911 tCO2eq/year to 21,552 tCO2eq/year. The emission status analysis revealed that Scope 1 LNG emissions were not related to production volume but were correlated with the number of employees and utility equipment within the 'A' company. Scope 2 electricity emissions were found to be related to production volume, particularly showing a correlation with utility equipment that operates as a base load. Scope 3 steam emissions were not related to production volume but were correlated with the industrial complex's temperature.
한국어
논문에서는 중견·중소기업의 배출량 산정 및 배출량 현황 분석을 위한 효과적인 방법론을 제시하기 위해, 반월·시화 산업단지에 소재한 PCB 가공 전문기업을 테스트베드로 선정하여 중견·중소기업의 배출량 산정 및 배출량 현황 분석 연구를 진행했다. 반월·시화 산업단지 소재 기업의 온실가스 배출량 산정결과 기업의 제품 생산량이 늘어날수록 수요기업의 Scope1과 Scope2는 651 tCO2eq/year에서 832 tCO2eq/year, Scope2 17,911 tCO2eq/year에서 21,552 tCO2eq/year으로 늘어나는 양상을 보였다. 배출량 현황 분석 결과 Scope1 LNG는 온실가스 원단위 분석결과 생산량과 관계가 없고 기업 내부 식수 인원과 유틸리티 장비들과 상관관계가 있었다. Scope2 전력은 온실가스 원단위 분석결과 생산량과 관계가 있다. 특히 기저 부하 장비인 유틸리티 장비와 상관관계를 가지고 있었다. Scope3 스팀은 생산량과 관계가 없고 산업단지 온도와 상관관계가 있었다.
목차
Abstract
Ⅰ. 서론
1. 연구배경
2. 온실가스 배출량
3. 원단위
4. 원단위 배출량
Ⅱ. 배경 이론
1. 온실가스 배출량 산정 방식
2. 원단위 배출량 산정공식
Ⅲ. 본론
1. 연구 방법
2. Scope 단계별 온실가스 배출량 산정
3. 온실가스 산정 결과
Ⅳ. 결론
REFERENCES