영어

Among the government's carbon reduction policies, this study examines the improvement of window insulation performance when an external electric blind (EEB) is installed as a method of reducing primary energy consumption for heating in existing apartment house. As a result of the analysis, the reduction ratio of heating energy according to the installation of EEB was at -35% in the living room(LR) and -20% in the child bedroom(CR) in the south wall. Also, in the north wall, it was at -14% in the LR and -10% in the CR. However, when the reduction ratio is converted into an absolute amount, the difference by direction is very small, and it has been confirmed that there is a reduction effect of -7.7~-9.1[kWh/㎡yr] in the LR and -5. 7~ -5.9[kWh/㎡yr] in the CR.

한국어

본 연구는 정부의 탄소 저감 정책 중, 기존 공동주택의 난방용 1차 에너지 소비량를 줄이는 방법으로 외 부 전동 블라인드(EEB) 설치 시 창호 단열 성능 향상에 대해 검토한 것이다. 검토 결과, EEB 설치에 따른 난방 에너지 저감 비율은 남향일 때 거실(LR)에서 -35%, 자녀방(CR)에서 –20%로 산출되었고, 북향일 때 거실에서 –14%, 자녀방에서 –10%로 계산되었다. 단, 저감 비율을 절대량으로 환산할 경우, 방향별 차이는 매우 미미하고, 거실에서 –7.7~-9.1[kWh/㎡yr], 자녀방에서 –5.7~-5.9[kWh/㎡yr]의 저감 효과가 있는 것으로 검토되었다.

목차

요약
Abstract
Ⅰ. 서론
Ⅱ. 연구 방법
2.1 외부 전동블라인드(EEB)
2.2 건물 난방에너지 시뮬레이션
2.3 난방에너지 해석 조건
Ⅲ. EEB설치에 따른 난방에너지 개선 효과
Ⅳ. 결론
REFERENCES

저자정보

  • 김영탁 Youngtag Kim. (주)대륙컨설팅 대표이사
  • 이희동 Heedong Lee. (주)에코이지스 대표이사
  • 최원기 Wonki Choi. (주)송은산업 대표이
  • 황태연 Taeyon Hwang. 조선대학교 건축공학과 부교수
  • 오양기 Yangki Oh. 목포대학교 건축학과 교수

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.