과전류 조건에 따른 단열 다심관의 수냉각 성능 분석

원문정보

Analysis of Water Cooling Performance of Insulated Multi-Core Tube Under Overcurrent Condition

이태호, 김명준

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect.

목차

ABSTRACT
1.서론
2. 연구 방법
2.1 단열 다심관의 제조
2.2 전기 케이블의 과전류 정의
2.3 줄열(Joule heat)발생
2.4 과전류 조건에 따른 수냉각 실험 방법
3. 연구 결과
4. 결론 및 고찰
References