Accuracy analysis of artificial respiration and chest compressions when performing CPR using a mannequin by college students
초록
영어
The purpose of this study was to analyze the accuracy of artificial respiration and chest compressions using CPR mannequins for university students. First, in the number of chest compressions, subjects A, F, H, I, and J showed similar numbers from 60 to 63, respectively, which were much lower than the standard. Subjects B, D, E, and G showed 90 to 91 times, maintaining the normal range. However, C was rather high with 119 times. Second, the depth of chest compression was 58.60mm, and most of them were deeply compressed. Subject C was close to normal at 51mm, and subjects A to J were significantly higher at 55mm to 62mm. The reason seems to be the result of an unstable psychological state with no experience of chest compressions and a lack of self-confidence. Third, in terms of accuracy, subject E showed the lowest accuracy at 12%, and A~J showed 33%~80%. Experiment subject B showed 95% accuracy, which seems to be the result of D accurately recognizing the chest compression point through theoretical training during military service.
한국어
이 연구의 목적은 대학생을 대상으로 심폐소생술 마네킹을 사용하여 인공호흡과 흉부 압박의 정확도를 분석하 였다. 첫째, 가슴압박 횟수에서 실험대상자 A, F, H, I, J는 60회에서 63회로 각각 비슷한 횟수를 나타냈고, 기준보다 매우 낮았다. 실험대상자 B, D, E, G는 90회에서 91회로 나타나 정상범위를 유지하였다. 그런데 C는 119회로 다소 높게 나타났다. 둘째, 가슴압박 깊이는 58.60mm로 대부분 깊게 압박하였다. 실험대상자 C는 51mm로 정상에 근접하 였고, 실험대상자 A~J는 55mm~62mm로 유의하게 높게 나타났다. 그 이유는 가슴압박의 경험이 전혀 없는 불안정한 심리상태와 자신감이 부족한 결과로 보인다. 셋째, 정확도에 있어서, 실험대상자 E는 12%로 나타나 정확도가 가장 낮았고, A~J는 33%~80%로 나타났다. 실험대상자 B는 95%의 정확도를 보였는데, 이는 D가 군 복무 중 이론 교육을 통하여, 가슴압박 지점을 정확하게 인지한 결과로 보인다.
목차
Abstract
Ⅰ. 서론
Ⅱ. 심폐소생술 마네킹 측정 방법
1. 성인 심폐소생술 마네킹
2. 심폐소생술 정확도 측정 방법
Ⅲ. 성인 심폐소생술의 실험 구성
1. 실험대상자의 선정
2. 실험 조건
Ⅳ. 실험 결과 및 고찰
1. 심폐소생술 시행에 따른 전체 정확도 비교
2. 심폐소생술 사전 교육과 실습의 중요성
Ⅴ. 결론
References