원문정보
Damping Performance Evaluation of Hysteretic Strip Damper with Curvature
초록
영어
Purpose: The purpose of this study is to improve the irregularity of the stress-strain curve and to ensure accuracy when calculating the damping effect by preventing members from moving in the off-plane direction due to eccentricity when loads are applied. Method: The specifications of the steel strips used in this study are the same, but the curvature of the strips to constitute each damper is different. Each steel strip with different curvature was arranged in an triangle, three dampers with different curvature were made, and repeated load tests were conducted, and the amount of energy dissipation was calculated to measure the performance of the damper. Result: The amount of energy dissipation significantly decreases compared to the case where there is no initial curvature, and the change in the test energy dissipation amount according to the size of the curvature is not large, and the presence or absence of the hyperbolic rate is considered an important variable. Conclusion: The period is about 78.7% longer from T=0.3 to T=0.536sec, and the response spectrum acceleration is reduced from Sa=0.54g to Sa=0.229g, so the damping effect of the damper is sufficient.
한국어
연구목적: 이력형 댐퍼에 하중이 작용할 때 편심에 의해서 부재가 면외 방향으로 거동하는 것을 방지하 여 응력-변형율 곡선의 불규칙성을 개선하고 감쇠효과의 계산 시 정확성을 기하고자 하는 것이 본 연구 의 목적이다. 연구방법: 본 연구에서 사용하는 강재 스트립의 제원은 동일하게 하되 각각의 댐퍼를 구성 할 스트립의 곡률은 다르게 한다. 곡률이 다른 각각의 강재 스트립을 댐퍼 1개당 3개씩 정삼각형으로 배 치하여 곡률이 다른 5개의 댐퍼를 제작한 후 반복하중 실험을 수행하고, 에너지 소산량을 계산하여 댐 퍼의 감쇠성능을 측정하였다. 연구결과: 시험 결과, 댐퍼 중에서 초기곡률이 조금이라도 있는 경우는 없는 경우보다 에너지 소산량은 상당히 감소하지만, 곡률의 크기에 따른 에너지 소산량의 변화는 크지 않으며, 곡률의 유무가 중요한 변수로 사료된다. 결론: 댐퍼를 적용한 해석적 검토에서 주기는 T=0.3sec 에서 T=0.536sec로 약 78.7% 정도 장주기화 되었고, 응답 스펙트럼 가속도는 Sa=0.54g에서 Sa =0.229g 로 줄었으므로 댐퍼의 감쇠효과는 충분히 존재한다.
목차
요약
서론
연구동향
연구내용 및 방법
시험체의 제작
시험체의 재하시험
실험결과의 분석 및 고찰
댐퍼(시험체)의 감쇠성능 분석
예제 구조물의 동적거동 해석
결론
Acknowledgement
References