Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

원문정보

Hwajung Lee, Do Hoon Oh, Lee Yoo, Minsoo Chun

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/ min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes’ own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

목차

ABSTRACT
Introduction
Materials and Methods
1. Metallic Injection Port on Tissue Expander
2. Experiment Design
3. Measurement of Radioactivation
Results and Discussion
Conclusion
Conflict of Interest
Acknowledgements
Ethical Statement
Author Contribution
References

저자정보

  • Hwajung Lee Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Institute of Radiation Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
  • Do Hoon Oh Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Institute of Radiation Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
  • Lee Yoo Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Institute of Radiation Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
  • Minsoo Chun Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Institute of Radiation Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Clinical Trial Support Team, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.