원문정보
원격광학측정 장비(SkyDOAS)를 활용한 일관제철사업소 황산화물 배출량 평가
초록
영어
Solar Occultation Flux (SOF) is based on the Solar Infrared (IR) spectrum. The equipment measures vertically integrated concentrations along the wind and crosswinds of pollutants and provides total emissions. Flux is calculated as an estimate of contaminants excluding inflow from the windward side. In addition to SOF systems, UV/visible systems (SkyDOAS) are used for SO2 measurements. SkyDOAS measures scattered light in the zenith and does not utilize direct solar light in contrast to the SOF instrument. In this study, the total amount of sulfur oxide (SO2) emissions from the integrated steel mill located in Chungcheongnam-do was measured six times from December 20 to September 21 and compared with the emission data presented by the workplace. The average emission at a workplace was 322 kg/hr, and the equipment measurement results showed that the emission was twice as high as 638 kg/hr on average. For more accurate measurement, LIDAR will be used to improve the accuracy of wind direction and wind speed, and if only pollutants emitted from the workplace are measured and compared by minimizing emission interference from the outside, it will be possible to effectively manage the workplace.
한국어
원격광학측정장비(Solar Occultation Flux ; SOF)는 태양 적외선(IR) 스펙트럼을 기반으로 한다. 해당 장비는 오염물질 의 풍하 및 횡풍을 따라 수직 통합된 농도를 측정하여, 총 배출량을 제공한다. 플럭스는 풍상측의 유입을 제외한 오염물 질의 추정치로 계산된다. SOF 시스템 외, SO2 측정을 위해 UV/visible 시스템(SkyDOAS)를 사용했다. SkyDOAS는 천 정에서 산란된 빛을 측정하며, SOF와 다르게 직달광을 사용하지 않는다. 본 연구에서는 국내 일관제철소 중 한 개 사업 장을 대상으로 20년 12월부터 21년 09월까지 총 6회 황산화물(SO2) 배출량을 측정하고 사업장에서 제시한 배출량 자료 와 비교하였다. 사업장의 평균 SO2 배출량은 322 kg/hr 였으며, 장비 측정결과는 평균 638 kg/hr로 약 2배 높은 배출량을 나타냈다. 보다 정확한 측정을 위해서는 풍향·풍속의 정확도 향상을 위해 라이다를 이용하여 고도별 풍향·풍속 자료를 이 용할 예정이며, 사업장 내부 측정을 통해 외부에서의 배출량 간섭을 최소화하여 사업장에서 배출되는 오염물질만을 측정 하여 비교한다면 보다 정확한 사업장의 효과적인 관리가 가능할 것으로 판단된다.
목차
요약문
I. 서론
II. 연구 방법
1. 측정장비
2. 장비의 불확실성
3. 사업장 굴뚝 실시간 농도
4. 측정위치 및 일시
III. 결과 및 고찰
IV. 결론
사사
References