earticle

논문검색

LIB 습식분리막 열손상에 따른 발화위험성에 관한 연구

원문정보

A Study on the Risk of Ignition due to Thermal Damage to the LIB Wet Separation Membrane

김용훈, 이종두, 진원철, 장혜진

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

LIB-related fires are continuously increasing due to the increase in personal transportation means and the commercialization of electric vehicles. Among the LIB components, the separation membrane is the most important key material for stability, and there is a problem in that it is lost at the scene of a fire and cannot confirm its shape. Accordingly, fire statistics and cases were analyzed, and the experimental outline was established through theoretical consideration of the wet separation membrane, which is the most used as a personal transportation means. As for the experimental method, we conducted a study on the shrinkage rate and tensile strength of the wet separator according to thermal damage for each temperature change with five experimental variables using the wet separator, which plays an important role in the stability of the battery components, as a sample. Through this, the change in shrinkage rate and mechanical properties of the wet separator were derived to understand the fire of lithium-ion batteries caused by damage to the wet separator and to contribute to the fire investigation analysis technique.

목차

Abstract
1. 서론
1.1 연구배경 및 목적
1.2 화재통계 분석
1.3 이론적 고찰
1.4 화재사례 분석
2. 본론
2.1 실험 개요
2.2 실험결과
3. 결론
제언