Two β=0.10 cryomodules are required for the China Accelerator Driven Subcritical System (C-ADS) injector II accelerator. Flow design is of great importance in the performance of cryomodules, including thermal design, flow distribution, pressure drop and so on. This paper will study convection heat transfer of helium and relation among the pipe diameter, mass flow rate and Reynolds number. Furthermore, the influence of flow geometries on pressure drop and flow distribution will also be done. It was found that the theoretical flow distribution were in good agreement with the experimental data.
목차
1. INTRODUCTION
2. FLOW SCHEME OF THE CRYOMODULE
3. FLOW THERMAL DESIGN
4. FLOW DISTRIBUTION AND PRESSURE DROP
5. CRYOMODULE PERFORMANCE AND DISCUSSION
6. CONCLUSIONS