초록

영어

This study analyzed the effects of the all-in-one automatic fire shutter (hereinafter referred to as “all-in-one shutter”) installed along the fire compartment in a five-story high school building on the evacuation time by using the Pathfinder simulation program. When the all-in-one shutter was added as a new variable, the evacuation time was delayed, indicating insufficient evacuation safety. The evacuation time exceeded the appropriate standard when the evacuation exit was designated to the students in the present state of being placed on the 2nd, 3rd, and 4th floors and the all-in-one shutter was activated. When students were placed on the 1st, 2nd and 3rd floors under the same conditions, the evacuation time was also greatly exceeded. However, when the width of the entrance was set to 130cm, the evacuation time was almost the same as when the all-in-one shutter was not installed. In high-rise school buildings, the bottleneck caused by all-in-one shutters is becoming a major factor in evacuation barriers. To ensure the evacuation safety of school buildings, it has been judged that evacuation education and training to predict the evacuation time required through the all-in-one shutter entrance and induce an evacuation procedure suitable for the standard evacuation time should be carried out in parallel. The implications of this study and suggestions for effective fire compartments and follow-up studies were discussed.

목차

Abstract
1. INTRODUCTION
1.1 The Need for Research
1.2 Prior Research Analysis and Research Purpose
2. BODY
2.1 Evacuation Simulation for Performance-Oriented Design
2.2 Target Building and All-in-one Shutter
2.3 Scenario Setting and Evacuation Time Analysis
2.4 Input Variables and Input Values
3. RESULTS AND ANALYSIS
3.1 Evacuation Time and Travel Distance According to the Width of the Entrance
3.2. Bottleneck According to the Width of the All-in-one Shutter Entrance
4. CONCLUSION
REFERENCES

저자정보

  • Lee Soon Beom Doctor, Gunsan Jeil High School, 142 Gyeonggijang-ro, Gunsan-si, Jeollabuk-do, Korea
  • Kong Ha Sung Associate professor, Dept. of Fire Protection and Disaster Prevention, Woosuk Univ, 443 Samnye-ro, Samnye-eup, Wanju-gun, Jeollabuk-do, Korea
  • Lee Jai Young Professor, Dept. of Disaster Safety & Firefighting, Konyang Cyber Univ, 158 Gwanjeodong-ro, Seo-gu, Daejeon, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.