Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
목차
1. 서론
2. 연구방법
2.1 전산유체역학 해석 모델
2.2 유량 측정 시스템의 계통오차 확인
2.3 펌프 현장 성능시험 결과 개선
3. 연구결과 및 고찰
3.1 전산유체해석 결과
3.2 유량 측정 시스템 계통오차 평가 결과
3.3 유량 측정 시스템의 계통오자를 반영한 펌프 성능시험 결과
4. 결론