원문정보
ON-OFF identification of quartz heater through soot deposition analysis
초록
영어
A combustion experiment was performed to confirm whether the heater was turned ON or OFF, to prove the hypothesis of a fatal fire which is presumed to be caused by the quartz heater contact with a combustible material. Considering that one of the two quartz tubes has relatively strong deposition of soot particles, we established hypothesis that the soot deposition of turned-on quartz tube would be expected weaker, while turned-off quartz tube would be stronger. As a result of performing soot deposition experiment on 8 quartz tubes with the flame of a kerosene burner in a chamber that simulated a compartment, all the results were consistent with the hypothesis. Therefore, the hypothesis was verified as a fact, and we obtained reference data that could be used in similar fire scene investigation.
한국어
석영관 히터와 가연물 접촉에 의해 발생한 것으로 추정되는 화재 변사 사건의 가설 을 입증하기 위하여 히터의 ON-OFF 여부 확인을 위한 연소실험을 수행하였다. 사례의 석영관 히터는 2구의 석영관 중, 한 개의 그을음이 비교적 강한 점에 착안하여 ON 상 태의 석영관에는 그을음 부착이 약하고, OFF 상태의 석영관은 그을음 부착이 강할 것 이라는 가설을 설정하였다. 구획실을 모사한 체임버 내에서 등유 버너의 화염으로 8개 의 석영관에 그을음 부착실험을 수행한 결과, 가설과 일치하는 결과가 나타났다. 이로 써 가설을 사실로써 입증하고, 추후 유사사건에서 사용 가능한 레퍼런스 데이터를 획 득하였다.
목차
Abstract
1. 서론
1.1 연구의 배경
1.2 관련 사례
1.3 연구의 목적
2. 이론적 고찰
2.1 그을음
2.2 석영관 히터
2.3 선행연구
3. 실험
3.1 실험 방법
3.2 실험 결과 및 고찰
4. 결론
후기
참고문헌