earticle

논문검색

변압기 잔류자속 측정에 관한 연구

원문정보

A study on the Measurement of Residual Flux for Transformer

김영학

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In previous studies to obtain the residual magnetic flux of the transformer using the leakage magnetic flux, a transfer function was used. The transfer function was consisted with the leakage magnetic flux measured outside the transformer and the residual magnetic flux measured at the moment passing through the two ± residual points. In this study, a method of calculating the ratio of the maximum operating leakage flux to the residual leakage flux was proposed The advantage of this method is to avoid the uncertainty of the transfer function due to current noise. Then, the noise of the sensor was measured to investigate the effect of the drift of the noise on the measurement results. Comparing the residual leakage magnetic flux density with 80nT of the drift noise, 66 times or more at a distance of 10 mm and 5 times or more at a distance of 100 mm were obtained. 100mm was the maximum measurement distance to obtain the residual magnetic flux.

한국어

누설자속으로 변압기의 잔류자속을 구하는 기존의 연구에서는 전달함수를 이용하였다. 전달함수는 변압기 의 ±의 두 잔류 점을 지나는 순간에 측정한 잔류자속과 동일한 순간에 변압기 밖에서 구한 누설자속으로 구하였 다. 본 연구에서는 전달함수를 구하지 않고 동작 최대의 누설자속과 잔류자속에 의한 누설자속의 비를 계산하여 잔류자속을 구하는 방법이 가능함을 확인하였다. 이 방법의 장점은 전류잡음으로 인한 전달함수의 불확정성을 피 하는 것이다. 그리고 센서의 잡음을 측정하여 잡음의 드리프트가 측정결과에 미치는 영향을 조사하였다. 잔류 누 설 자속밀도를 센서의 드리프트인 80nT와 비교하면 거리 10mm에서는 약 66배, 100mm에서는 5배 이상이었다. 측정거리 100mm는 본 연구에서 얻어진 잔류자속을 구하기 위한 최대 측정 거리였다.

목차

요약
Abstract
1. 서론
2. 실험방법
3. 결과 및 고찰
4. 결론
REFERENCES

저자정보

  • 김영학 Young-Hak Kim. 부경대학교 전기공학부 교수

참고문헌

자료제공 : 네이버학술정보