원문정보
A Study on the Possibility of Ignition in a Heating System Using PolyEthylene Terephthalate
초록
영어
This study is about the possibility of ignition and the cause of fire in a heating system using PolyEthylene Terephthalate ("PET heating film"). The fire case of PET heating film was investigated and the ignition point of each sample was analyzed through DSC-TGA. Based on this, the temperature measurement of heating element, the ignition test when the heating element disconected, and the connection part is damaged, the ignition test when the compression terminal is in incomplete contact, and the ignition possibility test of thermostat were conducted. As a result of the reenactment test, it is less possible to be on fire when the temperature sensor of the thermostat fails, but if the combustor and connection are damaged, if the compression terminal is in incomplete connection, it is possible to ignite due to the thermostat. From the research result, we are going to establish standards for fire investigation techniques and raise safety by raising awareness of the correct installation, importance of use, and the risk of fire in operation, finally it is contributing to the prevention of fire and helping to improve the quality of life of the people.
목차
1. 서론
1.1 연구 배경 및 필요성
1.2 연구 내용 및 목적
1.3 화재 사례
2. 관련 이론
2.1 난방필름의 종류
2.2 PET 난방필름의 구성 및 시공
2.3 DSC-TGA에 의한 재료 분석
2.4 PET 난방필름의 발열 원리
3. 실험조건 및 방법
3.1 PET Film의 온도측정 실험
3.2 PET Film의 훼손 시 발화시험
3.3 압축단자의 불완전 접촉 시 발화실험
3.4 온도조절기의 발화실험
4. 실험결과 및 고찰
4.1 PET Film의 온도측정 실험 결과 및 분석
4.2 PET Film의 훼손 시 발화시험 결과 및 분석
4.3 압축단자의 불완전 접촉 시 발화실험 결과 및 분석
4.4 온도조절기의 발화실험 결과 및 분석
5. 결론
참고문헌