원문정보
A Study on the Fire Risk of Polyurethane Foam in Construction Site
초록
영어
Polyurethane foam is often used as an insulation material in modern society due to its excellent insulation function, light weight and low density. As a result, fires are occurring frequently at construction sites using polyurethane foam. Due to the characteristics of polyurethane foam, the spread of fire is fast and toxic gases erupt in large quantities, causing property damage and human damage Most of the causes of the fire are caused by carelessness of workers during heat of work around the area, such as welding spark and torch use, with polyurethane foam applied. In response, this study experimented with the possibility of direct ignition on polyurethane foam applied using welding spark, grinder, and torch, which are the heat of works mainly used in construction sites. Experiments show that the applied polyurethane foam was easily ignited by welding spark, torches, and oil vapor except grinder spark. The purpose of the project is to prevent fires by prohibiting heat work such as welding at polyurethane foam work places and thoroughly observing and supervising prescribed fire safety rules.
목차
1. 서론
1.1 연구 배경 및 목적
2. 이론적 배경
2.1 폴리우레탄폼(Polyurethane foam)의 정의
2.2 폴리우레탄폼 결합반응
2.3 폴리우레탄 제조공정
2.4 폴리우레탄 폼의 생성
2.5 폴리우레탄 폼의 분류
3. 공사장 폴리우레탄폼 관련 화재 사례
3.1 화재사례 Ⅰ
3.2 화재사례 Ⅱ
4. 화재 재현 실험
4.1 실험개요
4.2 실험내용 및 방법
4.3 재현실험 결과
4.4 폴리우레탄폼 연소생성물 분석 실험
5. 결론
참고문헌