earticle

논문검색

전기요와 라텍스 혼용 사용 시 축열에 의한 화재위험성 연구

원문정보

A Study on the Risk of Fire due to Heat Storage When Using a Combination of Electric Blanket and Latex

김재혁, 김중수, 이대우, 박태용

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

This study reconstructed the actual fire site to study the fire hazard caused by heat storage when using a combination of electric blanket and latex mattress. In addition, the combustion patterns and carbonization patterns of each batch were compared and analyzed in the event of a fire due to heat storage by differently arranging the electric blanket and latex mattress. As a result of the experiment, latex showed higher fire risk due to heat storage compared to general bedding. In addition, it was proved that the combustion and carbonization types were different when the order of the latex arrangement was different based on the electric blanket. Through the results of this study, fire-detection algorithm were drawn to reconstruct and restore the ignition mechanism and fire scene in the event of a fire caused by heat storage due to the use of a mix of electric blanket and latex.

목차

Abstract
1. 서론
1.1 연구배경
1.2 연구의 필요성
1.3 연구과제 선정 이유
2. 이론적 고찰
2.1 전기장판의 개요
2.2 전기요 온도조절기의 구성
2.3 전기요 열선의 구성
2.4 라텍스 개요
2.5 훈소 개요
2.6 선행연구 검토
3. 전기요와 라텍스 배치순서에 따른 축열에 의한 화재재현실험
3.1 연구가설
3.2 실험장치(시료)
3.3 실험개요
4. 결론
4.1 온도조절기 정상작동에 의한 축열에 의한 발화 가능성
4.2 전기요와 라텍스 배치순서에 따른 축열 화재시 연소 및 탄화형태 차이점
4.3 전기요 발열선의 전기적 요인과 축열에 의한 화재시 차이점 분석
4.4 화재감식기법 개발
참고문헌

저자정보

  • 김재혁 Kim Jae Hyok. 강원도소방본부 광역화재조사
  • 김중수 Kim Jung Soo. 강원도소방본부 광역화재조사
  • 이대우 Lee Dae Woo. 강원도소방본부 광역화재조사
  • 박태용 Park Tae Young. 강원도소방본부 광역화재조사

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 5,100원

      0개의 논문이 장바구니에 담겼습니다.