원문정보
A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses
초록
영어
Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.
한국어
연구목적: 본 연구는 방화관리자 및 건물 관계인이 피난안전성능 향상 계획 수립 시, 한정된 예산을 고 려하여 피난안전성능 개선 항목 선정에 도움을 주는 수치해석 DB 구축 방향 수립이 목적이다. 연구방 법: 직통계단형 아파트 1개동과 복도형 1개동을 선정하여 정량적 평가기법인 CFD기반 피난안전성평 가를 수행하였다. 연구결과: 직통계단형 아파트는 방화구획 항목에서의 피난허용시간이 스프링클러설 비 등 피난허용시간보다 약 130%이상 높게 나타났다. 결론: 방화관리자 및 건축물 관계인은 적법하게 유지관리하고 직통계단형 공동주택에서는 “주거세대 별도 방화구획”을 우선 적용하는 것이 피난안전 성이 가장 개선되고, 층간 방화구획과 스프링클러설비를 상시 유지보수 및 강화하는 것이 효과적일 것 으로 판단된다. 복도형 공동주택에서는 연기확산이 직통계단형 공동주택보다 제한적인 특성을 고려하 여 소화설비의 유지보수가 우선되어야 할 것으로 사료된다.
목차
요약
서론
연구방법
피난안전성평가
피난안전성평가 대상 공간 선정
화재시나리오 설정
피난안전성평가 수행결과
면적별 방화구획
층간 방화구획
주거세대별 별도 방화구획
스프링클러설비
옥내소화전설비
소결
결론
References