Permeability Characteristics of Geosynthetics Vertical Barrier Connections for the Prevention of Contaminants Diffusion
초록
영어
Purpose: In this study, we used hydrophilic waterstop used in geosynthetics vertical barrier system to evaluate the performance of impermeability under sealing conditions. Method: ASTM D5887 and ASTM D6766 were applied to determine the capability of the connection during the geosynthetics vertical barrier system. Hydrophilic waterstop was saturated in each solution and the weight, thickness, and volume changes were analyzed over elapsed time. Hydrophilic waterstop was installed at the geosynthetics vertical barrier system connection to evaluate the permeability characteristics. Results: As the expansion reaction time of hydrophilic waterstop increased relatively under saline conditions, the decrease in permeability also showed a smaller decrease in fresh water. Furthermore, the method of engagement of the geosynthetics vertical barrier system showed somewhat better performance of the impermeability due to the large pressure resistance caused by the roll joint type than interlock type. Conclusion: In urban pollutants, which can estimate the outflow of pollutants such as oil storage facilities and industrial complexes, proactive response technologies that can prevent the contaminant diffusion can significantly reduce the damage.
한국어
연구목적: 본 연구에서는 토목섬유 연직차수시스템에 사용되는 팽창 지수재를 사용하여 지수재의 팽 창에 따른 차수성능을 평가하였다. 연구방법: 토목섬유 연직차수 공법 적용시 연결부에 대한 투수능을 판단하기 위하여 ASTM D5887과 ASTM D6766을 준용하였다. 팽창 지수재를 각 용액에 포화시킨 후 시간경과에 따른 무게, 두께, 부피 변화를 분석하였으며, 토목섬유 연직차수벽 연결부에 팽창지수재를 설치하여 투수 특성을 평가하였다. 연구결과: 염수조건에서 지수재의 팽창반응 시간이 상대적으로 늘 어남에 따라 투수능의 저하도 담수에서 보다 작은 감소폭을 나타내었다. 또한 토목섬유 연직차수재료 의 결속 방법에 따라 롤 이음방식이 인터록 방식 보다 수두차에 의한 압력저항이 커서 차수성능이 다소 우수하게 나타났다. 결론: 주유소, 유류저장시설 및 산업단지 등 오염물의 유출을 추정할 수 있는 도심 지 오염원에서는 오염물질 확산을 방지할 수 있는 사전대응 기술이 피해규모를 현격하게 감소시킬 수 있다.
목차
요약
서론
실험방법
투수능 실험 결과
용액 종류에 따른 지수재 반응 특성 평가 결과
이음부에 지수재를 적용한 토목섬유 연직차수벽의 투수능 특성 평가
결론
References