Purpose & Method: The purpose of this study is the theoretical study on the durability standard of ground structures monitoring sensors. A survey on the durability criteria for construction monitoring sensors of domestic construction companies and the income tax implementation regulations, the standard years of contents such as buildings and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. Result: The durability criterion such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the ground structure, is 8 to 10 years. Conclusion: The actual durability analysis by comparing the reliability of various monitoring sensors installed in dams at home and abroad, As a result of comprehensive study on the loss and damage rate of the maintenance monitoring sensor installed in the tunnel, the proper durability period of the built-in type monitoring sensor such as domestic pore pressure meter and earth pressure meter installed in the structure or the ground is 5 to 8 years it seems reasonable.
한국어
연구목적 및 방법: 본 논문은 지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구로 국내 건설공 사 발주기관의 건설 계측센서에 대한 내구연한 기준과 조달청의 건설계측 및 건설기계 관련 내용연수 기준을 분석하였다. 연구결과: 지반구조물에 설치되기 전 조달청에서 물품 자체로 구매하는 경사계와 변형률계 등의 내구연한 기준은 8년에서 10년을 제시하고 있다. 결론: 국내외 댐에 설치된 각종 계측센 서의 신뢰성 비교를 통한 실제적인 내구연한 분석과 터널에 설치된 유지관리 계측센서의 경과연수에 대한 손망실율 등을 종합 검토한 결과 구조물이나 지반에 설치된 국내 간극수압계 및 토압계 등의 매립 식 계측센서의 적정 내구연한은 5년에서 8년이 합리적인 것으로 판단된다.
목차
요약
서론
조달청 건설 계측센서의 물품관리 내용연수 기준 분석
건설 계측센서의 실제적인 내구연한 분석
국내 댐 계측센서의 실제적인 내구연한 분석
국외 댐 계측센서의 실제적인 내구연한 분석
터널 유지관리 계측센서의 손망실율에 의한 내구연한 분석
결론
Acknowledgement
References