earticle

논문검색

<학술연구>

써큐레이터의 플라스틱 후면 커버 성형용 금형에 적용된 형상 적응형 냉각 채널의 효과

원문정보

Effect of Conformal Cooling Channels Applield to Mold for Plastic Back Cover of Circulator

한성렬

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The longest process in the injection molding process is the cooling process of the molded product. Therefore, shortening the cooling time is key to reducing the injection molding cycle time. For fast cooling time, the production of conformal cooling channels using metal 3D printing instead of the conventional linear cooling channels is continuously increasing. In this study, the cooling effect of the conventional linear cooling channel application and the conformal cooling channel application using metal 3D printing was compared in the design of the back cover molding mold of the circulator that has been widely used recently. The comparison of the cooling effect was based on the mold temperature and the molded product temperature for a certain period of time after completion of molding. It was confirmed that the time required to eject from the mold with the conformal cooling channel to the ejecting temperature of the molded product was reduced by 28.7%, and the maximum temperature of the mold was also reduced by 40%.

목차

ABSTRACT
1. 서론
2. 본론
2.1 써큐레이터 백 커버
2.2 성형해석 모델
2.3 성형해석 결과
3. 결론
후기
References

저자정보

  • 한성렬 Seong-Ryeol Han. Member, Associate Professor, Department of Metalmold Design Engineering, Kongju Nation University

참고문헌