원문정보
신월 빗물저류배수시설 감세지 깊이에 따른 바닥 압력 분포 특성 분석 연구
초록
영어
Shinwol rainwater storage and drainage system is a large-scale urban underground facility for flood protection to supplement insufficient drainage capacity of the existing cities. For the smooth flow of flood water into the main tunnel, several conditions are considered to determine the type of energy reduction facility to be installed below the drop shaft. In this study, a hydraulic model experiment was conducted to calculate the most appropriate depth of plunge pool for Shinwol rainwater storage and drainage system. The experimental scenarios were designed with three depths of plunge pool and six discharges. It is found that the maximum pressure on the bottom surface increased for all three depths of plunge pools when the inflow discharge increased. The change in the location with the maximum and minimum pressure according to the increase in the inflow discharge for each scenario was considered to be due to a rotatory force in the upper drop shaft. This study found the scenario B as the optimal depth for Shinwol rainwater storage and drainage system.
한국어
신월 빗물저류배수시설은 기 개발된 도시의 부족한 배수 능력을 보완하기 위하여 지하에 설치하는 대규모 도시홍수 방어 시설물이다. 본 터널로의 원활한 홍수 유입을 위하여 수직유입구 하부에 설치 하는 감세시설의 형태는 여러 가지 조건을 고려하여 결정되어진다. 본 연구에서는 신월 빗물저류배 수시설의 적정 감세지 깊이를 산정하기 위하여 수리모형실험을 수행하였는데 실험 조건은 감세지 조건 3가지와 유입 유량조건 6가지에 대하여 수행하였다. 그 결과 유입유량이 증가할수록 깊이가 다른 3가지 감세지 시나리오 모두 바닥면에서의 최고압력은 증가하였다. 최대 압력의 경우 시나리오 B와 C에서 비슷한 것으로 분석되었다. 그리고 깊이가 다른 3가지 감세지 시나리오에서 유량이 증가 함에 따라 최고압력, 최소압력 측정위치가 변화하는 것은 상부 수직갱에서의 회전력에 의한 것으로 판단된다. 본 연구의 결과를 바탕으로 신월 빗물저류배수시설의 적정 감세지 깊이는 시나리오B가 가장 최적 인 것으로 판단된다.
목차
Ⅰ. 서론
Ⅱ. 연구동향
Ⅲ. 수리모형실험
1. 신월 빗물저류배수시설 개요
2. 수리모형실험 개요
3. 수리모형실험 조건
Ⅳ. 수리모형실험 결과
1. 시나리오A에서의 감세지 바닥면 압력분포 특성
2. 시나리오B에서의 감세지 바닥면 압력분포 특성
3. 시나리오C에서의 감세지 바닥면 압력분포 특성
4. 적정 감세지 깊이 선정
Ⅴ. 결론
감사의 글
References
국문초록