초록

영어

In the past, the U.S. NRC(Nuclear Regulatory Commission) strictly required testing of the EDG for NPP through Reg.Guide 1.108 Rev 1. However, these test requirements acted as a deterioration and wear factor for diesel engines, and are now applying Reg.Guide 1.9 Rev 3, which relaxed regulatory requirements and improved performance monitoring. After applying the new regulatory guidelines in this study, the EDG analyzed the performance of the combustion chamber. As a result, there were no signs of deterioration or decreased performance of the current EDG. This is due to slow start, short operation time, the use of high quality fuel oil and proper maintenance. On the other hand, if the performance is proven, it is judged that proper period extension of cylinder maintenance is possible.

목차

ABSTRACT
1. 서론
2. 실험설비 및 연구 방법
2.1 분석 장비
2.2 대상설비
2.3 진단방법
2.4 엔진 성능 평가
2.5 사용 연료유
3. 성능분석 결과
3.1 EDG 열성능 관련 운전변수 추이분석
3.2 엔진 상태진단 결과
4. 결론
References

저자정보

  • 강승희 Seung-Hee Kang. Member, Senior Research Eng-ireer, Mechanical Engineering Laboratory, KHNP CRI
  • 김명훈 Myeong-Hun Kim. Member, Research Engineer, Mechanical Engineering Laboratory, KHNP CRI

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원