earticle

논문검색

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

초록

영어

This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 WHTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

목차

Abstract
1. INTRODUCTION
2. CONTACTLESS CURRENT CHARGE TESTS
2.1. Current charge characteristics of CSFE
2.2. Current charge tests of full-scale HTS field winding
3. OUTPUT CHARACTERISTIC ANALYSIS
4. CONCLUSION
ACKNOWLEDGMENT
REFERENCES

저자정보

  • Yoon Seok Chae Department of Electrical Engineering, Jeju National University, Jeju,63243, Korea
  • Ho Min Kim Department of Electrical Engineering, Jeju National University, Jeju,63243, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.