earticle

논문검색

Original Research

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

초록

영어

Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 cm3 facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

목차

ABSTRACT
Introduction
Materials and Method
1. Improvement of Energy-Weighted Algorithm
2. RPM System under Test and Spectrum Measurement Condition
Results and Discussion
1. Spectrum Analysis of Moving Sources
2. Source Identification Test
Conclusion
Conflict of Interest
Acknowledgements
Author Contribution
References

저자정보

  • Hyun Cheol Lee Department of Radiation Convergence Engineering, Yonsei University, Wonju, Korea
  • Bon Tack Koo Department of Radiation Convergence Engineering, Yonsei University, Wonju, Korea
  • Chang Il Choi Korea Institute of Nuclear Safety, Daejeon, Korea
  • Chang Su Park Korea Institute of Nuclear Safety, Daejeon, Korea
  • Jeongwan Kwon Korea Institute of Nuclear Safety, Daejeon, Korea
  • Hong-Suk Kim Korea Institute of Nuclear Safety, Daejeon, Korea
  • Heejun Chung Korea Institute of Nuclear Nonproliferation and Control, Daejeon, Korea
  • Chul Hee Min Department of Radiation Convergence Engineering, Yonsei University, Wonju, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.