초록

영어

The feedwater heaters are critical components in a nuclear power plant. As the operation years of heaters go by, the maintenance costs required for continuous operation increase. Integral drains cooler is the separate heat exchanger combined in the heater shell. The integral drains cooler must be isolated from the other zones. The integral drains cooler must be free from leakage and the entrance into the zone be sealed against the entrance of steam from the condensing zone. Cause of tubes leakage since tubes replacement is the same as the cause before tubes replacement. Therefore, feedwater refurbishment method was selected by heater internal structure condition.

목차

ABSTRACT
1. 서론
2. 급수가열기 내부 운전 특성
3. 급수가열기 전열관 교체 전 손상 경험
3.1 응축영역 전열관 손상 분석
3.2 배수냉각영역 전열관 손상 분석
4. 급수가열기 전열관 교체 후 손상 경험
4.1 급수가열기 교체 방법
4.2 전열관 부분 교체 후 전열관 손상
5. 결론