영어

The aim of this study is to propose the optimal location of outrigger-belt truss system. To accomplish this objective, a structure design of 70 stories building was performed by MIDAS-Gen. In this paper, the main variables of this study were the stiffness of outrigger-belt truss, the outrigger position in plan, and so on. For the purpose of this research, we examined the lateral displacement in top floor, the axial force distribution of outrigger, the axial force distribution of exterior columns in the building model, etc. The optimum location of outrigger-belt truss system was proposed in this analysis study. Also, it is verified that the research results can be helpful in acquiring the structure design data for finding the optimal location of outrigger-belt truss system in the high-rise building.

한국어

본 연구는 아웃리거-벨트 트러스 구조의 최적위치를 제시하고자 70층 규모의 초고층 건물을 대상으로 MIDAS-Gen을 활용하여 구조설계를 진행하였다. 그리고 본 논문에서 주요한 해석 변수는 아웃리거-벨트 트러스의 강성, 아웃리거의 구조평면상 위치 등으로 하였다. 본 연구에서는 최상층에 발생한 수평변위, 아웃리거에 작용하는 축하중의 분포, 해석모델에 외곽 기둥에 작용하는 축하중의 분포 등을 분석하였다. 본 해석연구에서는 아웃리거-벨트 트러스 구조시스템의 최적위치를 제시하였다. 그리고 본 연구의 결과는 초고층 아웃리거-벨트 트러스 구조시스템의 최적위치를 찾는데 필요한 구조설계 데이터를 확득하는데 도움이 된다고 사료된다.