영어
Comprehensive utilization of tungsten tailings resources not only solves environmental problems but also creates huge economic benefits. The high content of iron impurity in tungsten tailings will have adverse effect on the downstreamcomprehensive utilization, whether flotation or pickling. In this paper, the Superconducting High Gradient Magnetic Separation(S-HGMS) is used to remove of Fe impurities from tungsten tailings. The optimal experimental parameters are as follows: background magnetic induction intensity is 3.0T, slurry flow velocity is 500ml/min. The Fe removal rate of Fe was 68.8% and the recovery rate was 59.53%.
목차
1. INTRODUCTION
2. MATERIALS AND METHODS
2.1. Materials
2.2. Experimental system
3. RESULTS AND DISCUSSION
3.1. Dependence of magnetic field strength
3.2. Effect of slurry velocity on experiment
4. CONCLUSIONS
ACKNOWLEDGEMENTS
REFERENCES