earticle

논문검색

Optimization approach of insulation thickness of non-vacuum cryogenic storage tank

초록

영어

Cryogenic insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Insulations are listed in order of increasing performance and, generally, in order of increasing cost. The specific insulation to be used for a particular application is determined through a compromise between cost, ease of application and the effectiveness of the insulation. Consequently, materials, representative test conditions, and engineering approach for the particular application are crucial to achieve the optimum result. The present work is based on energy cost balance for optimizing the thickness of insulated chambers, using foamed or multi layered cryogenic shell. The considered insulation is a uniformly applied outer layer whose thickness varies with the initial and boundary conditions of the studied vessel under steady-state radial heat transfer. An expression of the optimal insulation thickness derived from the total cost function and depending on the geometrical parameters of the container is presented.

목차

Abstract
1. INTRODUCTION
2. DETERMINATION OF OPTIMAL THICKNESS
3. RESULTS AND INTERPRETATION
4. FINAL CONCLUSIONS
REFERENCES

저자정보

  • Hocine MZAD Department of Mechanical Engineering, Badji Mokhtar University of Annaba, P.O. Box 12, DZ−23000, Algeria
  • Abdallah HAOUAM Department of Mechanical Engineering, Badji Mokhtar University of Annaba, P.O. Box 12, DZ−23000, Algeria

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.