earticle

논문검색

<생산기술>

토글식 사출성형기의 하중측정에 관한 연구

원문정보

A Study on the Weight Load Measurement of Toggle Type Injection Molding Machine

정현석

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In this study, the injection pressure of 31 MPa and clamping force of 1,000 kN toggle electric injection molding machine were used to measure the load transmitted to the frame during injection molding and to use it as the design basis data. In general, the toggle structure is composed of a movable plate, tie bars, crossheads, toggle links, toggle pins, base plates, etc and The material is spherical graphite cast iron(FCD 400). In this study, it was found that there was a 1.3% safety factor by calculating the clamping force in the structure of the five-point toggle link system. In addition, Expected static bottom load, Expected dynamic additional load, Maximum expected additional load, and Maximum weight load were measured using tensile measurements and presented as important basic design data of the assembly.

목차

ABSTRACT
1. 서론
2. 토글링크 시스템 구조
3. 실험장치 및 방법
4. 결과 및 고찰
5. 결론
References

저자정보

  • 정현석 Hyun-Suk Jung. Department Semiconductor quality measurement of Korea Polytechnic Ⅱcolleges Anseong campus

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.
      ※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.